Product Description
- Main Input Voltage: 100 V || 120 V || 200 V || 208 V || 230 V
- Number Of Cables: 2
- Provided Equipment: Documentation CD || Installation guide || Operations and maintenance manual
Contractual warranty
- Warranty: 1 year (parts only)
Environmental
- Storage Relative Humidity: 0-95 %
- Ambient Air Temperature For Operation: 0-50 °C
- Ambient Air Temperature For Storage: 0-50 °C
- Storage Altitude: 0-15000 ft
- Relative Humidity: 0-95 %
- Acoustic Level: 79 dBA
General
- Air Flow: 1600 ft³/min
Communications & Management
- Control Panel: Multi-function LCD status and control console
Physical
- Height: 191.8 cm
- Mounting Mode: not rack-mountable
- Color: Black
- Width: 73.7 cm
- Depth: 25.4 cm
- Net Weight: 77.27 kg
Offer Sustainability
- Circularity Profile: ENVEOLI1512008_V1
- Environmental Disclosure: ENVPEP1512008_V1
- Sustainable Offer Status: Green Premium product
- Lead Free: Yes
- Eu Rohs Directive: Pro-active compliance (Product out of EU RoHS legal scope)
- Reach Regulation: Free of Substances of Very High Concern above the threshold
- Reach Free Of Svhc: Yes
Input
- Input Power: 1200 W
- Input Frequency: 50/60 Hz
Overview
- Lead Time: Usually in Stock
- Presentation: High-density equipment creates an environment where traditional air distribution methods are often not effective. Densely packed enclosures can cause IT equipment to overheat, resulting in downtime. The Rack Air Removal Unit SX captures exhaust heat, returns the warm air to the plenum and eliminates hot spots from the data center. Through automatic fan speed control based upon temperature, the fans will self-adjust for optimal performance. With a unit-mounted LCD display, users can view temperatures at the rack, monitor alarm conditions and adjust unit set points. The integrated network management card allows for remote monitoring and control. This space-saving solution mounts to the back of either the NetShelter SX or VX enclosure, requiring zero U space.
Conformance
- Product Certifications: cUL Listed || CE || UL Listed || VDE
- Standards: EN 55022 Class A || EN 55024 || FCC Part 15 class A || ICES-003 || IEC 61000-3-2 || IEC 61000-3-3
Spec Sheet
Rack Air Removal Unit SX Firmware v3.7.2 - apc_hw02_aos394_raru_372.exe
Rack Air Removal Unit SX Firmware v3.1.1 - apc_hw02_aos314_raru311.exe
Rack Air Removal Unit SX Installation (Manual) - ASTE-6Z2RV3_R4_EN (pdf)
Rack Air Removal Unit: Release Notes v 3.1.1 (Application), 3.1.4 (AOS) - AKAR-74LJKK_R1_EN (pdf)
Rack Air Removal Unit SX Installation (Manual) - ASTE-6Z2RV3_R4_EN_SRC (pdf)
ACF402 - Rack Air Removal Unit SX - ACF402__-_Rack_Air_Removal_Unit_SX (dwg)
Rack Air Removal Unit SX Application Guidelines - DRON-6QKTBG_R0_EN (pdf)
Firmware
Rack Air Removal Unit SX Firmware v3.7.1 - apc_hw02_aos392_raru371.exeRack Air Removal Unit SX Firmware v3.7.2 - apc_hw02_aos394_raru_372.exe
Rack Air Removal Unit SX Firmware v3.1.1 - apc_hw02_aos314_raru311.exe
User guide
Release Notes Rack Air Removal Unit (RARU) - MLAN-8KLJRF_R2_EN (pdf)Rack Air Removal Unit SX Installation (Manual) - ASTE-6Z2RV3_R4_EN (pdf)
Rack Air Removal Unit: Release Notes v 3.1.1 (Application), 3.1.4 (AOS) - AKAR-74LJKK_R1_EN (pdf)
Rack Air Removal Unit SX Installation (Manual) - ASTE-6Z2RV3_R4_EN_SRC (pdf)
Technical Drawing
ACF402 - Rack Air Removal Unit SX - JSHR-6NUCP8_R1_EN (pdf)ACF402 - Rack Air Removal Unit SX - ACF402__-_Rack_Air_Removal_Unit_SX (dwg)
Application Notes
Rack Air Removal Unit SX Application Guidelines - DRON-6QKTBG_R0_EN_SRC.zipRack Air Removal Unit SX Application Guidelines - DRON-6QKTBG_R0_EN (pdf)