Product Description
- [Ue] Rated Operational Voltage: 400 V off-load plugging-in and unplugging, with supply switched on)IEC 60439-1 || 480 V off-load plugging-in and unplugging, with supply switched on)CSA || 480 V off-load plugging-in and unplugging, with supply switched on)UL || 600 V plugging-in and unplugging, with supply switched off)CSA || 600 V plugging-in and unplugging, with supply switched off)UL || 690 V plugging-in and unplugging, with supply switched off)IEC 60439-1
- Network Type: AC
- Product Or Component Type: busbar
- Bar Length: 1100 mm
- Product Name: HK
- Range: Linergy
- Enclosure/Cubicle Width: 1200 mm
- [Ie] Rated Operational Current: 160 A 35 °C
- Number Of Tap-Offs: 54
- Number Of Conductors: 4
- Device Application: distribution
Contractual warranty
- Warranty: 18 months
Complementary
- Bar Width: 45 mm
- Network Frequency: 50/60 Hz
- Protection Type: aM fuses In = 160 A, Isc = 100 kA, Ie = 160 A || gF fuses In = 160 A, Isc = 100 kA, Ie = 160 A || NS160H circuit breaker In = 160 A, Isc = 36 kA, Ie = 160 A || NS160H circuit breaker In = 160 A, Isc = 70 kA, Ie = 160 A
- Connections - Terminals: connector 2.5-70 mm² flexible with cable end || connector 2.5-70 mm² rigid
- Net Weight: 2.1 kg
- Mounting Position: vertical using side stop AK5BT01 on mounting plates AK5PA || horizontal
- Flame Retardance: V0 conforming to UL 94
- [Ui] Rated Insulation Voltage: 600 V CSA || 600 V UL || 690 V IEC 60439-1
- Tightening Torque: 10 N.m
- Width: 81 mm
- Depth: 82 mm
- I²T On Activation: 10000000 A².s
- Peak Current: 25 kA
Offer Sustainability
- Rohs Exemption Information: Yes
- Mercury Free: Yes
- Environmental Disclosure: ENVPEP120206EN
- Sustainable Offer Status: Green Premium product
- Toxic Heavy Metal Free: Yes
- Reach Regulation: Free of Substances of Very High Concern above the threshold
- California Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Reach Free Of Svhc: Yes
- Weee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation: Pro-active China RoHS declaration (out of China RoHS legal scope)
- Eu Rohs Directive: Compliant
Environment
- Product Certifications: UL || LROS (Lloyds register of shipping) || DNV || CSA
- Standards: IEC 60439
- Ip Degree Of Protection: IPxx B conforming to IEC 60529
- Fire Resistance: 850 °C IEC 60695
Spec Sheet
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187 (pdf)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-isometric (dwg)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-top (dxf)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-front (dwg)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-left (dwg)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-back (dxf)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-right (dxf)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-bottom (dwg)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-isometric (dxf)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-back (dwg)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-front (dxf)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-bottom (dxf)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-right (dwg)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-top (dwg)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-left (dxf)
AK5 JB… - AK5 PC Busbar systems - Removable power sockets - Instrcution sheet - 131937101A50+08 (pdf)
AK5 PA... Component mounting plates incorporating tap-off - 1319372_01A55 (pdf)
AK5 BT01 Side Stop - 1319436_01A55 (pdf)
Linergy HK - AK5JB - AK5PC - AK5PA - Instruction Sheet - EAV6376201 (pdf)
AK5 Mounting clip - 1319432_01A55 (pdf)
Catalogue TeSys 2019 - Chapter B1- Busbar systems Linergy BZ HK - B1+-+Systèmes+de+jeux+de+barres+de+puissance_FR+(web) (pdf)
CAD
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_3D-simplified (stp)LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187 (pdf)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-isometric (dwg)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-top (dxf)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-front (dwg)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-left (dwg)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-back (dxf)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-right (dxf)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-bottom (dwg)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-isometric (dxf)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-back (dwg)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-front (dxf)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-bottom (dxf)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-right (dwg)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-top (dwg)
LINERGY - HK JDB 4P 160A - 3D CAD - MCADPP0003187_2D-left (dxf)
Instruction sheet
AK5 PE... Extension plates - 1319378_01A55 (pdf)AK5 JB… - AK5 PC Busbar systems - Removable power sockets - Instrcution sheet - 131937101A50+08 (pdf)
AK5 PA... Component mounting plates incorporating tap-off - 1319372_01A55 (pdf)
AK5 BT01 Side Stop - 1319436_01A55 (pdf)
Linergy HK - AK5JB - AK5PC - AK5PA - Instruction Sheet - EAV6376201 (pdf)
AK5 Mounting clip - 1319432_01A55 (pdf)
Catalog
Digest Catalog 18: Contactors and Starters-IEC (SEP 2022) - 0100CT1901_SEC-18_SEP2022 (pdf)Catalogue TeSys 2019 - Chapter B1- Busbar systems Linergy BZ HK - B1+-+Systèmes+de+jeux+de+barres+de+puissance_FR+(web) (pdf)