Product Description
- Range Of Product: Easergy T300
- Device Short Name: SC150
Complementary
- Communication Port Support: 2 ETHERNET RJ45
- Measurement Voltage: LPVT single or three phases)0-10 V AC 50/60 Hz || VTs single or three phases)47-240 V AC 50/60 Hz
- Number Of Outputs: switch 2 digital (relay)
- Continuous Output Current: 8 A
- Memory Capacity: 4 MB
- Output Voltage: motor 12...127 V DC || motor 90...220 V AC
- Protection Type: ANSI 50/51 : overcurrent || ANSI 50N/51N : earth fault || ANSI 67 : directional phase overcurrent || ANSI 67N : directional earth fault || ANSI 47 : negative sequence overvoltage || ANSI 27 : undervoltage || ANSI 59 : overvoltage || ANSI 59N : neutral voltage displacement || ANSI 37 : phase undercurrent
- Type Of Measurement: apparent power || voltage || active and reactive power || active and reactive energy || power factor || current || frequency || apparent energy
- Product Or Component Type: MV switch controller
- Irms Rated Making Capacity: 15 A 4 s
- Measurement Current: 5-5 A || 1-1 A
- Maximum Switching Voltage: 440 V AC
- Number Of Inputs: 8 digital IEC 61131-2 type 3
- [Us] Rated Supply Voltage: 12...48 V DC +/- 20 %
- Communication Port Protocol: IEC 60870-5-104
- Power Consumption In Va: 2 VA
- Software Function: assistance in commissioning and operating the installation || security/authority verification || alarm || event log || Operating/Status report || reports and diagrams
- Control Type: status illuminated push-button
- Data Recording: sag and swell logs || harmonics logs || min/max of instantaneous values || demand values || event logs || sequence of event recording || counter || current value before fault
- Breaking Capacity: 2000 VA
- Analogue Input Type: 4 current 0.01...35 A 0.001 Ohm)
- Type Of Measurement: current class 0.5 || voltage class 0.5 || energy class 1 IEC 61557-12
- Synchronisation Time Between Inputs: 1 ms
- Power Quality Analysis: voltage unbalance || individual harmonics || voltage sag and swell detection || harmonic distortion || voltage magnitude
Offer Sustainability
- Rohs Exemption Information: Yes
- Mercury Free: Yes
- Environmental Disclosure: ENVPEP1605007
- Sustainable Offer Status: Green Premium product
- Reach Regulation: Reference contains Substances of Very High Concern above the threshold
- California Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Weee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation: X
- Circularity Profile: ENVEOLI1605007
- Eu Rohs Directive: Compliant
Environment
- Product Certifications: CE
- Ik Degree Of Protection: IK07 IEC 62262
- Ambient Air Temperature For Operation: -40-70 °C
- Height: 140 mm
- Standards: IEC 60255-27 || IEC 61557-12 || IEC 62586-1 || IEC 61000-4-30:class S || IEC 61850
- Electromagnetic Compatibility: electrical fast transient/burst immunity test level 4criteria A IEC 61000-4-4 || conducted RF disturbances level 3criteria A IEC 61000-4-6 || conducted disturbance emission level 4criteria A IEC 61000-4-16 || 100 kHz damped oscillating wave level 3criteria A IEC 61000-4-12 || radiated radio-frequency electromagnetic field immunity test level 4criteria A IEC 61000-4-3 || immunity to voltage dipscriteria A IEC 61000-4-29 || electrostatic discharge level 4criteria B IEC 61000-4-2 || surge immunity test level 3criteria A IEC 61000-4-5 || magnetic field at power frequency level 5criteria B IEC 61000-4-8 || conducted and radiated emissionsclass A EN 55022
- Net Weight: 0.515 kg
- Fixing Mode: clip-in DIN rail)
- Ambient Air Temperature For Storage: -40-85 °C
- Relative Humidity: 5-95 % IEC 60068-2-30
- Ip Degree Of Protection: body IP2X IEC 60529 || front IP4X IEC 60529
- Type Of Installation: indoor || outdoor in cabinet
- Mechanical Robustness: vibrations 10-2000 Hz 1 gn 10 cycles IEC 60068-2-6 || bumps 10 gn 16 ms 1000 bumps non energized IEC 60068-2-29 || shocks 10 gn 11 ms 3 pulses in operation IEC 60068-2-27
- Width: 45 mm
- Depth: 140 mm
- Operating Altitude: 6561.68 ft (2000 m)
Spec Sheet
Digest Catalog 05: Protection, Control, and Energy Automation (SEP 2022) - 0100CT1901_SEC-05_SEP22-2022 (pdf)
T300 Database User manual - NT00391-+08+-+T300+Database (pdf)
PowerLogic HU250 Installation guide - NHA77925-10_PowerLogic_HU250_Installation_Guide (pdf)
PowerLogic SC150 Installation guide - NHA91857-08_PowerLogic_SC150_Installation_Guide (pdf)
PowerLogic T300 User manual - NT00378-11-EN+PowerLogic+T300+User+Manual (pdf)
Easergy T300 Quick start - NT00383-EN-07+-+Quick+start+T300 (pdf)
Easergy Builder - User Manual - SE-S856-MSS_Easergy+Builder+-+User+Manual_EN_4.0 (pdf)
Easergy Builder software - Easergy+Builder_1.7.24.0_Release_Notes (pdf)
Easergy Builder software - Easergy+Builder+1.7.24.0.zip
Catalog
PowerLogic Easergy T300 Catalog - NRJED314621EN_(Web) (pdf)Digest Catalog 05: Protection, Control, and Energy Automation (SEP 2022) - 0100CT1901_SEC-05_SEP22-2022 (pdf)
User guide
PowerLogic HU250 without wireless - PKR45928-00_PowerLogic_HU250_without_Wireless_Installation_Guide (pdf)T300 Database User manual - NT00391-+08+-+T300+Database (pdf)
PowerLogic HU250 Installation guide - NHA77925-10_PowerLogic_HU250_Installation_Guide (pdf)
PowerLogic SC150 Installation guide - NHA91857-08_PowerLogic_SC150_Installation_Guide (pdf)
PowerLogic T300 User manual - NT00378-11-EN+PowerLogic+T300+User+Manual (pdf)
Easergy T300 Quick start - NT00383-EN-07+-+Quick+start+T300 (pdf)
Easergy Builder - User Manual - SE-S856-MSS_Easergy+Builder+-+User+Manual_EN_4.0 (pdf)
Software - Release
PowerLogic T300 Firmware - PowerLogic+T300+Release+2.8.2.zipEasergy Builder software - Easergy+Builder_1.7.24.0_Release_Notes (pdf)
Easergy Builder software - Easergy+Builder+1.7.24.0.zip