Product Description
- Range Of Product: Telemecanique Emergency stop rope pull switches XY2C
- Product Or Component Type: latching emergency stop rope pull switch
- Housing Colour: red RAL 3000
- Overvoltage Category: class I EN/IEC 61140
- Device Short Name: XY2C
Complementary
- Reset: by pull button
- Number Of Cables: 1
- Terminals Description Iso N°1: (11-22)NC || (21-22)NC
- Short-Circuit Protection: 10 A cartridge fuse gG EN/IEC 60269
- Positive Opening: with EN/IEC 60947-5-1
- [Ithe] Conventional Enclosed Thermal Current: 10 A
- Marking: CE
- Head Material: PA (polyamide)
- Local Signalling: color indicator
- Net Weight: 0.455 kg
- [Uimp] Rated Impulse Withstand Voltage: 6 kV EN/IEC 60947-1
- Trigger Cable Maximum Length: 20 m
- Connections - Terminals: screw clamp terminal, 1 x 0.5...2 x 1.5 mm²
- Contacts Type And Composition: 2 NC
- [Ui] Rated Insulation Voltage: 500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14
- [Ie] Rated Operational Current: 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A
- Contact Operation: slow-break
- Distance Between Cable Supports: 5-5 m
- Mechanical Durability: 100000 cycles
- Cable Entry Number: 1 tapped entry Pg 13.5 cable gland
- Compatibility Code: XY2CJ
- Body Material: zamak
- Trigger Cable Anchor Point: RH or LH side
- Safety Reliability Data: B10d = 500000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5
- Cover Material: galvanised steel
- Tightening Torque: 0.8-1.2 N.m
- Maximum Resistance Across Terminals: 25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A
- Safety Level: can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Offer Sustainability
- Rohs Exemption Information: Yes
- Mercury Free: Yes
- Environmental Disclosure: ENVPEP1407003EN
- Sustainable Offer Status: Green Premium product
- Reach Regulation: Reference contains Substances of Very High Concern above the threshold
- California Proposition 65: WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Eu Rohs Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Ambient Air Temperature For Operation: -25-70 °C
- Standards: EN/IEC 60947-5-1 || CSA C22.2 No 14 || UL 508 || EN/IEC 60947-5-5 || EN/ISO 13850 || machinery directive 2006/42/EC || EN/IEC 60204-1 || work equipment directive 2009/104/EC
- Product Certifications: UL category NISD emergency stop devices || CSA || CCC || EAC
- Shock Resistance: 50 gn 11 ms EN/IEC 60068-2-27
- Vibration Resistance: 10 gn 10-150 Hz)EN/IEC 60068-2-6
- Ip Degree Of Protection: IP66 IEC 60529 || IP67 IEC 60529
- Ambient Air Temperature For Storage: -40-70 °C
- Protective Treatment: TC
Spec Sheet
XY2CJ... emergency stop trip wire switches (made in Indonesia) - Certificate for China compulsory product certification - CCC+2014010305692751+[XY2CJ+Indonesia]+2020-08-17 (pdf)
XY2CJ... emergency stop trip wire switches - CSA+2711121+XY2CJ+(v1.0) (pdf)
XY2CE/CED..., XY2CH... and XY2CJ... emergency stop trip wire switches - UL certification record - UL+Certification+Record+NISD.E352710+[XY2CE_CED+%26+XY2CH+%26+XY2CJ]+2019-09-04 (pdf)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-isometric (dwg)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-back (dwg)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-bottom (dxf)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-left (dxf)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_3D-simplified (stp)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-isometric (dxf)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-right (dwg)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-top (dxf)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-front (dxf)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598 (pdf)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-front (dwg)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-bottom (dwg)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-right (dxf)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-top (dwg)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-left (dwg)
XY2CJ... emergency stop trip wire switches - EC/EU declaration of conformity - ECEUDoC+EAV75564-06+[XY2CJ]+2022-04-27 (pdf)
Brochure
Sensors, Switches and Machine Safety Product Guide - 9006BR2201NAM_SensorsPano0622 (pdf)Certificate
XY2CJ... emergency stop trip wire switches (made in Indonesia) - CQC product certificate - CQC+2014010305692751+[XY2CJ+Indonesia]+2020-08-25 (pdf)XY2CJ... emergency stop trip wire switches (made in Indonesia) - Certificate for China compulsory product certification - CCC+2014010305692751+[XY2CJ+Indonesia]+2020-08-17 (pdf)
XY2CJ... emergency stop trip wire switches - CSA+2711121+XY2CJ+(v1.0) (pdf)
XY2CE/CED..., XY2CH... and XY2CJ... emergency stop trip wire switches - UL certification record - UL+Certification+Record+NISD.E352710+[XY2CE_CED+%26+XY2CH+%26+XY2CJ]+2019-09-04 (pdf)
Instruction sheet
XY2CJS/R/L... EMERGENCY STOP ROPE PULL SWITCH, Instruction Sheet - EAV69749_01_EN (pdf)CAD
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-back (dxf)Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-isometric (dwg)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-back (dwg)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-bottom (dxf)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-left (dxf)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_3D-simplified (stp)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-isometric (dxf)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-right (dwg)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-top (dxf)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-front (dxf)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598 (pdf)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-front (dwg)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-bottom (dwg)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-right (dxf)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-top (dwg)
Emergency stop rope pull switches Preventa XY2C, maxi cable length 30m, right or left anchor point - 3D CAD - MCADID0004598_2D-left (dwg)
Catalog
Emergency stop rope pull switches (XY2C range) catalog English 02/2020 - Catalogue+Emergency+stop+rope+pull+switches+XY2C+range (pdf)Environmental Disclosure
XY2CJS15 EMERGENCY STOP ROPE PULL SWITCH, Product Environmental Profile - ENVPEP1407003EN_V1 (pdf)Declaration of conformity
XY2CJ... emergency stop trip wire switches - UK declaration of conformity - UKDoC+JYT50780-01+[XY2CJ]+2022-04-27 (pdf)XY2CJ... emergency stop trip wire switches - EC/EU declaration of conformity - ECEUDoC+EAV75564-06+[XY2CJ]+2022-04-27 (pdf)